Overview:
The RB7 Multiple Relay Module incorporates seven (7) isolated form “C” relay outputs that can be activated via
positive (+) low current trigger inputs. Typical applications include the switching of alarm devices
(eg. annunciator, signals, etc.) from PGM outputs of alarm panels or from another source.
Specifications:
•12VDCto24VDCselectableoperation.
• Seven(7)independent(3VDCto24VDC@2mAminimum)positive(+)triggers.
• Seven(7)isolatedform“C”1amp/120VACor28VDCcontacts.
Boarddimensions(LxWxH):6.5”x3.25”x1”(165.1mmx82.6mmx25.4mm).
Installation Instructions:
1. MountRB7inthedesiredlocation/enclosure.
2. Connect12VDCto24VDCpowersupplytotheterminalsmarked[POS+]andeitheroftheterminalmarked[GND].
3. Connect3VDCto24VDCpositive(+)triggertoeachtriggerinputsmarked[INP1toINP7].
4. Triggeringinput1(INP1)activatesrelayoutput1(OUT1).Input2(INP2)activatesrelayoutput2(OUT2)etc.
5. Connectoutputdevicestoterminalsmarked[NC,C,NO]drycontacts.
INP5 INP6 INP7 GND POS+INP1 INP2 INP3 INP4 GND