AL1012ULACM converts a 115VAC 60Hz input into eight (8) independently controlled
12VDC Fail-Safe and/or Fail-Secure outputs with a total of 10 amp continuous supply cur-
rent. Outputs are activated by an open collector sink or normally open (NO) dry trigger input
from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will
route power to a variety of access control hardware devices including Mag Locks, Electric
Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-
Secure modes. This unit is designed to be powered by one common power source (factory
installed) which will provide power for both the board operation and locking devices, or
two (2) totally independent power sources, one (1) providing power for board operation
and the other for lock / accessory power. The FACP Interface enables Emergency Egress,
Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm discon-
nect feature is individually selectable for any or all of the eight (8) outputs.
AL1012ULACM
Power Supply/Chargers w/Multi-Output
Access Power Controllers Rev. DSAL1012ULACM_01032013
Overview
Specifications
AL1012ULACM
Input:
• Input115VAC60Hzrated@1.9amp.
• Powersupplyinputoptions:
a) One (1) common power input for ACM8/
ACM8CB and lock power (factory installed).
b)Two (2) isolated power inputs - One (1)to power the
ACM8/ACM8CB and one (1) for lock
accessory power, (external power supply is
required). (Current is determined by the
power supply connected, not to exceed a
maximum of 10 amp total).
• Eight(8)AccessControlSystemtriggerinputs.
Inputoptions:
a) Eight (8) normally open (NO) inputs.
b)Eight (8) open collector inputs.
c) Any combination of the above.
Output:
• 12VDC@10ampsupplycurrent.
• Eight(8)independentlycontrolledoutputs.
Outputoptions:
Eight (8) Fail-Safe and/or Fail-Secure power outputs.
• Eight(8)auxiliarypoweroutputs(unswitched)
• Outputratings:
-Fusesarerated@3.5amp.
• Filteredandelectronicallyregulatedoutputs
(built-in power supply).
Features:
• FireAlarmdisconnect(latchingornon-latching)is
individually selectable for any or all of the
eight (8) outputs.
Features (cont’d):
• FireAlarmdisconnectinputoptions:
a) Normally open (NO) or normally closed (NC)
dry contact input.
b)Polarity reversal input from FACP signaling circuit.
• AlarmoutputrelayindicatesthatFACPinputis
triggered (form“C”contactrated@1amp28VDC
not evaluated by UL).
• Shortcircuitandthermaloverloadprotection.
Visual Indicators:
• RedLEDsindicateoutputsaretriggered
(relays energized).
• GreenLEDindicatesFACPdisconnectistriggered.
• ACinputandDCoutputLEDindicators.
Battery Backup:
• Built-inchargerforsealedleadacidorgeltypebatteries.
• AL400ULXB(PowerSupplyBoard)maximum
charge current 0.7 amp.
• Automaticswitchovertostand-bybatterywhenACfails.
• Zerovoltagedropwhenunitswitchesovertobattery
backup (AC failure condition).
• Batteryfailandbatterypresencesupervision
(form “C” contact).
Electrical:
• Operatingtemperature:0ºCto49ºCambient.
• ACM8boardmainfuseisratedat10amp.
• BTU/Hr.:61.42BTU/Hr.
Mechanical:
• EnclosureDimensions(HxWxDapprox.):
15.5”(393.7mm)x12”(304.8mm)x4.5”(114.3mm)
- Accommodates up to two (2) 12AH batteries.
• Productweight(approx.):10.7lbs.(4.85kg).
• Shippingweight(approx.):12lbs.(5.44kg).