Overview:
Model Tempo2 Digital Test / Trigger Mode Timer is suitable for many applications that require a timed operation. e.g.
delayed egress with a programmable 1-60 second door release after delay expires, door prop alarm, door annunciator,
alarm swinger eliminator, etc. Digital display facilitates ease of programming and indicates time remaining before relay
activation. Daily/Weekly test mode can be used to trigger digital communicators or radio transmitters and provide Central
Stations with an alarm test signal.
Specifications:
•Input12or24VoltsACorDCoperation.
•Triggersviadrycontactclosure.
•OutputdryForm“C”contactsare2amp@120VAC/28VDC.
•LCDdisplayfacilitatesprogrammingandindicatescountdownstatus.
•Currentdraw:stand-by15mA,relayenergized30mA.
•Dualfunction:testtimer/oneshot.
•EEPrommemoryprotectsagainstlossofprogrammingduetopowerfailure.
•Boarddimensions(LxWxHapproximate):3”x2.5”x0.75”(76.2mmx63.5mmx19.05mm)
One-Shot Features (trigger activated):
• Programmablerelayactivationatthestartorendofthetimingcycle.
a.DelayedPulseMode:
- 1 to 60 sec. programmable pulse at the end of timing cycle.
b.DelayMode:
-Relaycanbeprogrammedtoenergizeorde-energizeduring
timingcycle(Digitallyadjustfrom1sec.-24hours).
Test Timer Options:
• Programmableweeklyordailytest.(Testcanbeprogrammedfor
aspecificdayandtime).
1. DepressandHoldConfirm SU00:00 willappearindisplay.
for 2 seconds until TestMode
2. Depress Advance SU00:00 will appear in display.
SetClock
3. DepressandHoldConfirm SU00:00 will appear in display.
fortwo(2)seconds Setday
EnterthecurrentdayoftheweekbydepressingAdvance
to make the selection.
4. DepressConfirm SU00:00 will appear in display.
Set hour
EnterthecurrenthourofdaybydepressingAdvance to make the selection.
5. DepressConfirm SU00:00 will appear in display.
Set min
EnterthecurrentminuteofdaybydepressingAdvance to make the selection.
6. Depress Confirm SU00:00 will appear in display.
TestMode
Tempo2 - One-Shot/Test Timer
Dry
relay
output
Advance
CNC NO
POWER
12-24
VDC/VAC
Dry
Trigger
IN1
Confirm
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - Tempo2 - One-Shot/Test Timer

Overview:Model Tempo2 Digital Test / Trigger Mode Timer is suitable for many applications that require a timed operation. e.g. delayed egress with a p

Seite 2 - Trigger Mode Programming:

- 2 - Tempo27. DepressAdvancetwice SU00:00 will appear in display. TestTime8. DepressandHoldConfirm SU00:00 will appear in display.

Seite 3 - Tempo2 Typical Applications:

Tempo2 - 3 - Tempo2 Typical Applications:Fig. 1-TimedDoorAnnunciator:DryrelayoutputAdvanceCNC NOPOWER12-24VDC/VACDryTriggerIN1ConfirmNormally o

Seite 4 - TRANSMITTER

- 4 - Tempo2Tempo2 Typical Applications (cont.)Fig. 5-TimedDoorLock:DryrelayoutputAdvanceCNC NOPOWER12-24VDC/VACDryTriggerIN1Confirm--+Normall