Rev. 050404
ALTV615DCUL Series
CCTV Power Supplies
Installation Guide
Models Include:
ALTV615DC44ULM ALTV615DC44ULCBM
- 6-15VDC @ 4 amp - 6-15VDC @ 4 amp
- Four (4) Fuse Protected Outputs. - Four (4) PTC Protected Outputs.
ALTV615DC48ULM ALTV615DC48ULCBM
- 6-15VDC @ 4 amp - 6-15VDC @ 4 amp
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
ALTV615DC416UL ALTV615DC416ULCB
- 6-15VDC @ 4 amp - 6-15VDC @ 4 amp
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
ALTV615DC616UL ALTV615DC616ULCB
- 6-15VDC @ 6 amp - 6-15VDC @ 6 amp
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
ALTV615DC416ULCBM*
- 6-15VDC @ 4 amp
- Sixteen (16) PTC Protected Outputs.
* Same except for enclosure size
For models with line cord installed : For 3-wire add suffix “3” e.g. ALTV615DC44ULM3.
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - ALTV615DCUL Series

Rev. 050404ALTV615DCUL Series CCTV Power SuppliesInstallation GuideModels Include:• ALTV615DC44ULM • ALTV615DC44ULCBM- 6-15VDC @ 4 amp - 6-15VDC @ 4

Seite 2

Overview:These Altronix DC CCTV Power Supplies provide 6-15VDC distributed via fuse or PTC protected outputs for poweringCCTV Cameras, heaters and oth

Seite 3 - Terminal Identification:

7. Connect devices to terminals marked [1P - 1N through 4P - 4N] on PD4/PD4CB board, [1P - 1N through 8P - 8N] on PD8/PD8CB, [1P - 1N through 16P - 16

Seite 4 - Used on PTC Models

CAUTION: De-energize unit prior to servicing. For continued protection against fire hazardreplace fuse with the same type and rating 3.5A, 250V. Do no

Seite 5 - DC outputs

DoorCAUTION: De-energize unit prior to servicing. For continued protection against fire hazardreplace fuse with the same type and rating 3.5A, 250V.

Seite 6 - ALTV615DC416ULCBM

Black Lead White Lead 115VAC input50/60 HzXFMRPower Supply BoardTrimpotDC Outputs Class 2 Power LimitedOutput WiringCAUTION: De-energize unit prior to

Seite 7 - RightLeft

5.10"6.5625"3.25"3.25"5.10"5.10"3.25"1.00"10.50"1.00"1.00"1.00"1.40"1.20"1.40&qu

Seite 8 - II1ALTV615DCULSeries I14F

Altronix Corp.140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056web site: www.altronix.com, e-mail: [email protected], Lif