24VDC rated @ 8 amp max.
• Two (2) Class A or four (4) Class B outputs.
Two (2) Class A or two (2) Class B FACP inputs.
Two (2) NC dry contact trigger inputs.
Two (2) Class A or four (4) Class B
indicating circuits.
Two (2) Class B outputs may be paralleled for more
power on an indicating circuit.
One (1) Aux. Power Output @ 1 amp supply current
(w/battery back up).
Signal Circuit Trouble Memory - facilitates quickly
locating intermittent system trouble and eliminates
costly and unnecessary service calls. LED’s indicate a
prior fault (short, open, ground) has occurred on one
or more signaling circuit outputs.
2-wire Horn/Strobe Sync mode allows audible
notification appliances (Horns) to be silenced while
visual notification appliances (Strobes) continue
to operate.
Horn/Strobe sync protocols include:
CooperWheelock®, Gentex®,
System Sensor®, Faraday, Amseco.
Temporal Code 3 Mode.
Steady Mode.
Input to Output Follower Mode (maintains
synchronization of notification appliance circuits).
March Time.
Compatible with 12VDC or 24VDC fire panels.
Common trouble inputs and outputs.
Ground fault detection.
Input 115VAC.
AC fail supervision (form “C” contacts).
Low battery supervision (form “C” contacts).
Battery presence supervision (form “C” contacts).
Power supply, logic board, red enclosure, cam lock,
transformer & battery leads.
Enclosure:
- Combination knockouts are 1/2” and 3/4”
- Accommodates up to two (2)
12VDC/12AH batteries.
AL802ULADA weights:
Product weight: 10.7 lbs.
Shipping weight: 13.3 lbs.
AL802ULADA
NAC Power Extenders
Rev. AL802ULADA_A25K
Overview
Specifications
Agency Approvals
UL Listed Control Units and Accessories
for Fire Alarm Systems (UL 864) Ninth
Edition
Factory Mutual Approved.
NYC Department of Buildings Approved.
California State Fire Marshal Approved.
The AL802ULADA are extremely cost effective voltage regulated remote NAC
Power Extenders. They may be connected to any 24 volt Fire Alarm Control
Panel (FACP). Primary applications include Notification Appliance Circuit (NAC)
expansion (supports ADA requirements) and will provide auxiliary power to sup-
port system accessories.
CooperWheelock is a registered trademark of CooperWheelock. Gentex is a registered trademark of Gentex Corporation. System Sensor is a registered trademark of Honeywell.
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - NAC Power Extenders

• 24VDC rated @ 8 amp max.• Two (2) Class A or four (4) Class B outputs.• Two (2) Class A or two (2) Class B FACP inputs.• Two (2) NC dry contact tr

Seite 2 - Enclosure Dimensions

Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.comEnclosure Dimensions15.5”H x 12.23”W x 4.5”D12.230&qu

Kommentare zu diesen Handbüchern

Keine Kommentare